Search results for "Aqua regia"
showing 10 items of 16 documents
The determination of trace element concentrations in fly ash samples using ultrasound-assisted digestion followed with inductively coupled plasma opt…
2009
Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of trace element (chromium, copper, lead, nickel, vanadium and zinc) concentrations in fly ash samples was developed. All the measurements were performed in robust plasma conditions. Ultrasound-assisted digestion procedures using digestion solutions of aqua regia and hydrofluoric acid (HF) resulted in recovery rates of over 80% for all the analyte elements. Ultrasound-assisted two-step digestion with digestion solutions of 6 mL of HNO3 (Step 1) and 3 mL of HNO3 + 3 mL of HF (Step 2) resulted in recovery rates of over 92% for all the ana…
An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical em…
2007
Abstract A method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L min−1, auxiliary gas flow of 0.2 L min−1 and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-ass…
Atomic absorption spectrometric determination of molybdenum in lubricating oils with use of emulsions
1985
Abstract Samples (0.1 g) containing molybdenum disulphide are digested with aqua regia or with a (1 + 1) hydrofluoric/nitric acid mixture, without complete destruction of the matrix, and the molybdenum is determined in an air/acetylene flame, after emulsification with a non-ionic surfactant (Nemol K-39). The detection limit is ca. 30 μg Mo g−1, and the r.s.d. is 2.9% for 6 analyses of a sample containing 6.5 mg Mo g−1.
Simultaneous determination of As, Cd, Cr and Pb in aqua regia digests of soils and sediments using electrothermal atomic absorption spectrometry and …
2002
A method was developed for the simultaneous multi-element determination of As, Cd, Cr and Pb in aqua regia digests of soils and sediments using an electrothermal atomic absorption spectrometer with a transversely heated graphite atomizer and longitudinal Zeeman-effect background correction. A fast furnace program with no pyrolysis stage or chemical modifier was used, and the total duration of the time-temperature program of the graphite furnace was 45 s. The method detection limits calculated from blank samples were 9.5 μg l−1, 0.18 μg l−1, 6.2 μg l−1 and 2.5 μg l−1 for As, Cd, Cr and Pb, respectively. Sample preparation procedures are briefly described. The accuracy of the method was confi…
Multicommutation hydride generation atomic fluorescence determination of inorganic tellurium species in milk
2005
Abstract A multicommutated flow system has been developed for hydride generation, atomic fluorescence (HG-AFS) determination of tellurate (Te VI ) and tellurite (Te IV ) in milk samples. After a batch leaching of Te by sonication at room temperature for 10 min with aqua regia, sample slurries in acidic medium were merged with sodium borohydride and HCl to obtain data on Te IV . Another portion of the acidic slurry was mixed with KBr and passed through a reaction coil introduced inside a microwave oven to reduce quantitatively Te VI to Te IV which was analyzed by HG-AFS. The detection limit was 0.57 ng g −1 in the original samples. The linear range obtained was till 4 ng ml −1 and the averag…
Speciation of selenium and tellurium in milk by hydride generation atomic fluorescence spectrometry
2004
A simple, fast and highly sensitive method has been developed for the differentiation of Se and Te into their (IV) and (VI) oxidation states in milk samples by HG-AFS. This procedure involves a previous leaching of milk slurries by sonication with aqua regia for 10 min. Se(IV) and Te(IV) were determined by analysis of the samples without a pre-reduction step; being total Se and Te determined after reduction with KBr. The method provides limit of detection values (LOD) of 0.012 and 0.023 ng ml−1 for Se(IV) and Te(IV) respectively. Average relative standard deviation values of 10.5%, 3.9%, 12% and 12.5% were found for the determination of Se(IV), Se(VI), Te(IV) and Te(VI) in milk samples cont…
Non-chromatographic speciation analysis of arsenic and antimony in milk hydride generation atomic fluorescence spectrometry
2003
Abstract A rapid, high sensitivity method has been developed for the determination of As(III), As(V), Sb(III) and Sb(V) in milk samples by using hydride generation atomic fluorescence spectrometry. The method is based on the leaching of As and Sb from milk through the sonication of samples with aqua regia followed by direct determination of the corresponding hydrides both before and after reduction with KI. It was confirmed by recovery experiments on spiked commercially available samples that neither the reduced nor the oxidized forms of the elements under study or mixtures of the two oxidation states were modified by the room temperature sample treatment with aqua regia. The methodologies …
Determination of inorganic species of Sb and Te in cereals by hydride generation atomic fluorescence spectrometry
2011
A non-chromatographic fast, sensitive and easy method has been developed for the determination of Sb(III), Sb(V), Te(IV) and Te(VI) in cereal samples. The procedure is based on ultrasound assisted extraction and determination by hydride generation atomic fluorescence spectrometry (HG AFS). Preliminary studies were made in order to get the best extraction efficiency using 1 mol L-1 phosphoric acid, 1 mol L-1 nitric acid, aqua regia, 1 mol L-1 sulfuric acid and 6 mol L-1 hydrochloric acid. The extraction with aquaregia showed a clear interconversion of the species during the process, being H2SO4 the best extractant with efficiencies greater than 90% from the total content of Sb and Te quantif…
Determination of As, Sb, Se, Te and Bi in milk by slurry sampling hydride generation atomic fluorescence spectrometry
2003
A simple and fast analytical procedure has been developed for the determination of As, Sb, Se, Te and Bi in milk samples by hydride generation atomic fluorescence spectrometry (HG-AFS). Samples were treated with aqua regia for 10min in an ultrasound water bath and pre-reduced with KBr for total Se and Te determination or with KI and ascorbic acid for total As and Sb, the determination of Bi being possible in all with or without pre-reduction. Slurries of samples, in the presence of antifoam A, were treated with NaBH(4) in HCl medium to obtain the corresponding hydrides, and AFS measurements were processed in front of external calibrations prepared and measured in the same way as samples. Re…
Selective recovery of gold from electronic waste using 3D-printed scavenger
2017
Around 10% of the worldwide annual production of gold is used for manufacturing of electronic devices. According to the European Commission, waste electric and electronic equipment is the fastest growing waste stream in the European Union. This has generated the need for an effective method to recover gold from electronic waste. Here, we report a simple, effective, and highly selective nylon-12-based three-dimensional (3D)-printed scavenger objects for gold recovery directly from an aqua regia extract of a printed circuit board waste. Using the easy to handle and reusable 3D-printed meshes or columns, gold can be selectively captured both in a batch and continuous flow processes by dipping …